制药厂臭氧消毒系统验证方案下载
目 录
1.系统基本情况.................................................... 4
1.1 概述..........................................................4
1.2 基本情况......................................................4
1.3 维修服务......................................................4
2.验证目的........................................................ 4
3.验证范围........................................................ 5
4.验证机构组成.................................................... 5
4.1 验证委员会组成................................................5
4.2 验证小组成员..................................................5
5.职责............................................................ 6
5.1 验证委员会....................................................6
5.2 验证小组......................................................6
5.3 生产部........................................................6
5.4 工程部........................................................6
5.5 品质部........................................................7
6.验证方案的起草与审批............................................ 7
6.1 验证方案的起草................................................7
6.2 验证方案的审批................................................7
7.进度计划........................................................ 7
8.验证............................................................ 8
8.1安装确认..................................................... 8
8.1.1 安装确认的目的..............................................8
8.1.2 安装确认的原理..............................................8
8.1.3 文件资料....................................................8
8.1.4 风管清洁的确认..............................................9
8.1.5 风管漏风检测................................................9
8.1.6 安装确认的内容..............................................9
8.1.7 安装确认的方法..............................................9
8.1.8 可接受标准..................................................9
8.1.9 异常情况的处理..............................................9
8.1.10 起草标准操作程序..........................................10
8.1.11 结果与评定................................................10
8.2运行确认.................................................... 10
8.2.1 运行确认的目的.............................................10
8.2.2 运行确认的原理.............................................10
8.2.3 验证所需的仪器仪表.........................................11
8.2.4 运行确认的内容.............................................11
8.2.5 运行确认的方法.............................................11
8.2.6 可接受标准.................................................11
8.2.7 异常情况的处理.............................................11
8.2.8 结果与评定.................................................12
8.3性能确认.................................................... 12
8.3.1 性能确认的目的.............................................12
8.3.2 性能确认的原理.............................................12
8.3.3 性能确认的内容.............................................12
8.3.4 性能验证的周期.............................................12
8.3.5 监测方法...................................................12
8.3.6 性能确认的方法.............................................13
8.3.7 可接受标准.................................................13
8.3.8 异常情况的处理.............................................13
8.3.9 拟订日常监测程序及验证周期.................................13
8.3.10 结果与评定................................................13
9.验证结果及分析................................................. 14
10.附件.......................................................... 14
附件1:验证方案修改申请及批准书 ..........................................................15
附件2: 安装确认所需资料.........................................................16
附件3: 风管清洁确认记录.........................................................17
附件4: 风管检漏记录表..........................................................18
附件5: 安装确认记录..........................................................19
附件6: 验证所需仪器仪表校正表..........................................................20
附件7: 运行确认记录表.........................................................21
附件8: 臭氧消毒监测程序.........................................................24
附件9: 臭氧消毒效果监测记录表.........................................................26
附件10: 日常监测程序及验证周期........................................................30
8.3.7可接受标准
按臭氧消毒程序进行消毒操作后,取样监测,消毒间空气沉降菌应小于5CFU/皿,包材微生物残存量应小于5CFU/个(支)。连续进行监测3 批/次,所有各项指标均符合要求,可判定系统通过性能确认。
8.3.8异常情况的处理
臭氧消毒系统性能确认过程中,应严格按照设备标准操作程序、维护保养程序、取样检测标准操作程序及8.3.7(可接受标准)进行操作和判定。出现个别样品不符合标准的结果时,应按下列程序进行处理:
1.在不合格点重新取样(沉降菌)或重新取3 个包材(包材微生物残存量)检测一次不合格项目。重新检测的项目必须合格。
2.如挑战性实验不符合要求,应分析原因,作相应的处理,如延长消毒时间,重新进行一次试验,以确定不合格原因。
3.若属系统运行方面的原因,必要时报验证委员会,调整系统运行参数或对系统进行处理。
臭氧浓度的测定
采用供应商(承建商)提供的臭氧检测仪进行检测。在开始消毒前将臭氧检测仪置于消毒间中间位置,按其说明书或操作程序进行在线检测。该臭氧检测仪为&*型便携式臭氧检测仪。检测范围:0~50ppm,分辨率:0.01ppm;检测方式:扩展式;响应时间:小于15s;精度:1%F.S;工作温度:-20~50℃;工作湿度:0~95%。
附件下载:制药厂臭氧消毒系统验证方案下载